You are about to access the “Professional Information” area of the CeramTec Medical website which is solely for Medical and Pharmaceutical Professionals. Please confirm that you are a member of this professional group.
The 23rd Annual National Joint Registry (NJR) Report covers procedures through December 31, 2025, with hip volumes reaching record highs.
Here are the key data points from the year:
Across 120,338 primary hip procedures in 2025
Fixation: Uncemented 42.5%, hybrid 41.8%, cemented 12.3% (down from 53.2% in 2004).
Bearings: Hybrid ceramic-on-polyethylene (CoP) at 27.3% and uncemented CoP at 26.9% were the most common constructs. Uncemented and hybrid ceramic-on-ceramic (CoC) use fell to 1.8% and 0.1%, respectively.
Head size: 36 mm was the most common head size for the first time.
Revision reasons (single stage in the last 5 years): Aseptic loosening (33.0%), dislocation or subluxation (21.9%), periprosthetic fracture (19.9%).
20-year cumulative revision, uncemented: 5.61% CoP (95% CI 5.21%-6.04%), 6.22% CoC (95% CI 5.9%-6.55%), 8.22% MoP (95% CI 7.8%-8.66%).
20-year cumulative revision, hybrid: 4.91% CoP (95% CI 4.26%-5.65%), 5.61% CoC (95% CI 5.15%-6.12%), 5.92% MoP (95% CI 5.58%-6.26%).
The data show that outcomes depend on fixation, bearing, brand construct, and patient age. The registry advises surgeons to familiarize themselves with the performance of the specific construct they implant, particularly in younger patients.
This post reflects CeramTec’s summary of a peer-reviewed scientific publication and does not constitute clinical guidance, risk prediction for individual patients, or product-related recommendations. For product, safety, and risk information, always refer to the labeling of the legal manufacturer.